Product Brief
VIP4‑1A‑06(10243) belongs to VIP4‑1A series general‑purpose single‑phase one‑stage common‑mode AC power filter. Rated at 115/250VAC, 6A RMS Max with 50/60Hz operating frequency, it delivers excellent common‑mode and differential‑mode noise attenuation across 150kHz‑30MHz under 50‑ohm test system. It features max 0.3mA leakage current at 115VAC/60Hz and 0.6mA at 250VAC/50Hz. It passes 2000VAC line‑to‑ground and 1450VDC line‑to‑line one‑minute hi‑pot test, with insulation resistance ≥100MΩ@500VDC and working temperature ranging from ‑25℃ to +100℃. Multiple connection types including wire, solder lug, stud and terminal block are optional. Medical‑grade H‑type version and custom‑made solutions are available upon request. Certified by CQC, UL, CE, RoHS and REACH, this filter boasts compact structure, easy installation and high cost‑performance. High‑voltage versions above 380VAC are also optional for special‑demand projects.
Applications Household electrical appliances Precision measuring and laboratory testing instruments Small industrial control equipment Office electronic devices Automation peripheral equipment Various AC‑powered devices that need to suppress conducted electromagnetic interference to fulfill EMC compliance requirements
![VIP4-1A-06(10243) Single Phase IEC Socket EMC EMI Power Noise Filter For Precision Measuring Instrument Household Equipment 7]()
![VIP4-1A-06(10243) Single Phase IEC Socket EMC EMI Power Noise Filter For Precision Measuring Instrument Household Equipment 8]()
FAQ
Q1: What are the main electrical parameters of VIP4‑1A‑06(10243)?
A: Rated voltage is 115/250VAC, rated current is 6A RMS Max, operating frequency is 50/60Hz. Its operating temperature ranges from ‑25℃ to +100℃.Q2: What is the leakage current specification of VIP4‑1A‑06(10243)?
A: For each line‑to‑ground, the maximum leakage current is 0.3mA under 115VAC/60Hz, and 0.6mA under 250VAC/50Hz.Q3: What is the hi‑pot and insulation resistance requirement for this filter?
A: It can withstand 2000VAC line‑to‑ground and 1450VDC line‑to‑line for one‑minute hi‑pot test. The insulation resistance is no less than 100MΩ when tested at 500VDC between input/output and ground.Q4: What connection styles and special versions can I select?
A: Wire, solder lug, stud and terminal block terminals are optional. Medical‑grade H‑type version is available, and we can provide custom‑specific versions according to your project requirements.Q5: What is the attenuation performance of VIP4‑1A‑06(10243)?
A: It adopts one‑stage common‑mode circuit design, offering good common‑mode and differential‑mode noise attenuation within 150kHz‑30MHz. Insertion‑loss data is measured under 50‑ohm system for reference only, which helps customers for EMC performance evaluation.