Product Brief
VIP1‑1A‑03(10328) is a one‑stage common‑mode single‑phase EMC power filter with built‑in standard IEC inlet. Rated for 115/250VAC and 3A RMS, it works at 50/60Hz power frequency. It features low leakage current, high‑voltage withstand capability and wide operating temperature from ‑25℃ to +100℃. It provides great common‑mode and differential‑mode noise attenuation within 150kHz‑30MHz under 50‑ohm test system. Available with wire or solder‑lug output terminals. It complies with CQC, UL, CE, RoHS and REACH standards, supporting optional medical‑grade H‑type version and custom‑made modification upon request. Compact IEC‑integrated structure enables quick installation with high cost‑efficiency.
![VIP1-1A-03 (10328) Standard IEC Socket Electromagnetic Disturbance Damping Module Single Phase Power Signal Cleaner For Domestic Electronics & Laboratory Measuring Device 7]()
Applications
- Household electrical appliances
- Laboratory & precision measuring instruments
- Small‑size industrial control equipment
- Test & measurement devices
- Office electronic equipment
- Suitable for equipment requiring suppression of conducted electromagnetic interference on AC power lines
![VIP1-1A-03 (10328) Standard IEC Socket Electromagnetic Disturbance Damping Module Single Phase Power Signal Cleaner For Domestic Electronics & Laboratory Measuring Device 8]()
Characteristics:
(1) Voltage Rating: 115/250VAC
(2) Current Rating:
A. AT 115VAC: 3A RMS Max.
B. AT 250VAC: 3A RMS Max.
(3) Operating Frequency: 50/60Hz
(4) Leakage Current (Each Line to Ground):
A. AT 115VAC/60Hz: 2 μA Max.
B. AT 250VAC/50Hz: 5 μA Max.
(5) Hi‑pot Rating (For One Minute):
A. Line to Ground: 2000 VAC
B. Line to Line: 1450 VDC
(6) IR: 100M ohm AT 500VDC ANY Input or Output to Ground
(7) Temperature Range: -25℃ ~ +100℃
![VIP1-1A-03 (10328) Standard IEC Socket Electromagnetic Disturbance Damping Module Single Phase Power Signal Cleaner For Domestic Electronics & Laboratory Measuring Device 9]()
FAQ
Q1: What is the rated current and voltage of VIP1‑1A‑03(10328)?
A: Its rated voltage is 115/250VAC, rated current is 3A RMS Max, working frequency 50/60Hz.
Q2: What are the output terminal options for this filter?
A: Two output styles are available: wire lead terminals or solder lug terminals. You can select according to your cabinet wiring requirement.
Q3: How about the leakage current of VIP1‑1A‑03(10328)?
A: Max leakage current is 2μA @115VAC/60Hz, 5μA @250VAC/50Hz. Low leakage design fits precision and medical‑related scenarios.
Q4: What is the operating temperature range of this filter?
A: Operating temperature ranges from ‑25℃ to +100℃, stable performance for normal indoor equipment working environment.
Q5: Can I get medical‑grade version or customized modification for this model?
A: Yes. Medical‑special H‑type version is optional. We also support custom‑specific versions according to your technical requirements.