loading

The world's leading manufacturer of power filters.

High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 1
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 2
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 3
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 4
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 5
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 6
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 7
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 1
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 2
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 3
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 4
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 5
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 6
High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 7

High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices

Single Phase 10A EMC Filter,115‑250VAC,Good Interference Rejection Performance
Strict high‑pot and insulation tests guarantee high‑level electrical safety performance. It withstands 2000VAC line‑to‑ground and 500VDC line‑to‑line for one minute, together with more than 100M ohm insulation resistance at 500VDC. Such solid electrical properties avoid leakage risks and short‑circuit hazards, and support long‑term non‑stop continuous running under normal load for industrial onsite applications.
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product Introduction
    The VIP4‑2B‑10(10307) is a premium single-phase two-stage EMI power filter with a 10A rated current, designed to operate on 115VAC and 250VAC, 50/60Hz AC power systems. Featuring an optimized dual-stage filtering circuit design, this product provides superior insertion loss performance, effectively eliminating both common-mode and differential-mode high-frequency electromagnetic interference on power lines. The filter undergoes rigorous safety testing, offering 2000VAC line-to-ground withstand capability and insulation resistance above 100MΩ at 500VDC. Supporting an extensive working temperature range of -25℃ to +100℃ and adopting reliable solder terminal connection, it delivers stable, long-term anti-interference performance in various harsh working environments. It effectively protects sensitive electronic components from grid noise and enables end devices to comply with international EMC electromagnetic compatibility regulations.
    High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 8

    Application Scope & Usage
    This professional EMI filter is specially designed to eliminate conducted interference on AC power input lines. It provides bidirectional noise isolation: it shields equipment from high-frequency disturbance transmitted from the public power grid, and also prevents electromagnetic noise generated by the device itself from polluting the mains power supply. It is widely used in industrial control systems, automated machinery, CNC processing equipment, precision testing instruments, communication devices, switching power supplies, medical auxiliary equipment and high-end household electrical appliances. Installed at the AC input terminal of electrical equipment, it significantly enhances system stability, improves overall anti-interference performance, and helps finished products smoothly pass standard EMC certification tests.
    High Efficiency VIP4‑2B‑10(10307) Power Noise Filter Single Phase 10A Low Pass Filter For Household And Control Devices 9

    FAQ
    Q: Is grounding mandatory for EMI filter installation? A: Yes, proper grounding is essential for optimal filter performance. Most of the common-mode noise suppression capability relies on the grounding loop. Without reliable grounding, the filter’s noise attenuation efficiency will be greatly reduced, and electrical safety risks may occur. Standard grounding ensures full filtering effect and stable long-term operation.

    Q: What is the difference between common-mode noise and differential-mode noise? A: Differential-mode noise appears between live and neutral wires and mainly affects signal stability, while common-mode noise occurs between power lines and ground and is the main cause of EMC failure and equipment electromagnetic radiation. This two-stage filter suppresses both types of noise simultaneously, achieving comprehensive power line purification.

    Q: Can multiple EMI filters be used in series for better filtering effect? A: In general, series installation of multiple filters is not recommended and will not bring obvious improvement. Unreasonable series connection may cause impedance mismatch, resonance problems or increased leakage current. Selecting a matched two-stage high-performance filter according to actual load and interference conditions is the most effective and stable solution.

    Q: What causes EMC test failure even after installing an EMI filter? A: Poor filtering results are usually caused by non-standard installation, such as long grounding wires, mixed input and output wiring, unreasonable wiring routing, or unshielded cable layout. In addition, insufficient filter current grade and nearby high-frequency interference sources can also lead to unqualified EMC test results.

    Q: Are EMI filters universal for all electrical equipment? A: EMI filters are not fully universal. Selection must match the equipment’s actual working voltage, operating current and interference frequency characteristics. Different loads and application scenarios require corresponding single-stage or two-stage filters. Professional model selection ensures optimal noise reduction effect and equipment safety.

    Partner with the best.
    E-MAIL US
    vip6@szviip.com
    SUPPORT 24/7
    +86 19925448748
    CONTACT PERSON
    Vicky Lee
    Related Products
    Ready to work with us ?
    +86-19925448748
         +86-0755-29170376     
    Shenzhen VIIP Electronics Co., Ltd. is a professional EMC service provider. Mainly focusing on the R & D, production and sales of EMC anti-interference components.
    Contact Us

    2F building D Mao yuan industry area, Huan guan south road,

    Guan hu street, Long hua district, Shenzhen city

    Contact person: Vicky Lee

    Tel: +86 19925448748

    WhatsApp:86-18003057179

    Copyright © 2026 VIIP | Sitemap | Privacy Policy
    Customer service
    detect