loading

The world's leading manufacturer of power filters.

VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 1
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 2
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 3
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 4
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 5
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 6
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 7
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 1
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 2
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 3
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 4
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 5
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 6
VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 7

VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units

Compact AC Line Filter For Industrial Electronic Devices
Effective Suppression of Common‑mode & Differential‑mode EMI Noise Adopts mature LC filter circuit architecture. It delivers favorable insertion loss in 50‑ohm testing system, efficiently eliminates common‑mode and differential‑mode interference from AC power input. It helps finished products pass EMC related certification tests and reduce power‑caused signal disturbance for whole electronic system.
5.0
design customization

    oops...!

    no product data.

    Go to homepage
    inlet socket
    VIP4‑1A-03(B041W0674)

    Product Brief

    The VIP4-1A-03 is a robust single-phase AC EMI filter adopting optimized passive LC circuit configuration. With a 3A RMS continuous current rating, it supports 115VAC and 250VAC dual voltage input, perfectly matching global 50Hz and 60Hz mains power standards. Featuring minimal leakage current and exceptional high-voltage insulation strength, this filter delivers consistent electrical performance in a wide ambient temperature range from -25℃ to 100℃. Equipped with excellent insertion loss capability, it efficiently mitigates high-frequency common-mode and differential-mode electromagnetic interference on AC power lines. As a professional EMC supporting component, it enables end electronic devices to pass international electromagnetic compatibility certifications, maintains stable quality consistency in mass production, and guarantees reliable, trouble-free long-term operation for all AC-powered electrical and electronic equipment.
    VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 8

    Application Range & Usage

    This single-phase AC EMI filter is specially developed to suppress power grid noise and internal circuit electromagnetic interference, serving as a standard EMC optimization part widely applied in industrial equipment and civilian electronic products.
    Its mainstream application scenarios cover:
    • Industrial control devices and automated production systems
    • Switching power supplies, power adapters and charging equipment
    • Office automation facilities and consumer electronic products
    • Precision testing tools and professional measuring instruments
    • Household appliances fitted with standard AC power input ports
    Installed at the front-end AC power inlet of electronic equipment, the filter effectively isolates external high-frequency noise from the power grid and protects internal precision circuits from interference damage. Meanwhile, it restrains electromagnetic noise generated by device operation from backflowing into the public power grid, eliminates cross-interference between different electrical equipment, and stabilizes the overall system power supply environment.
    VIP4‑1A‑03( B041W0674 )Power Input Interference Suppression Filter Reliable Filter For Medical Related Electronic Units 9

    FAQ 

    Q1: What key parameters should I prioritize when selecting an EMI filter? A: The core selection parameters include rated working current, input voltage range, leakage current value, working temperature range and insertion loss curve. It is necessary to match the filter specifications with your equipment’s actual operating current, mains voltage and EMC failure frequency band to ensure optimal noise suppression and safe operation.
    Q2: Will EMI filters cause power loss for electronic equipment? A: Negligible power loss occurs during operation. Designed as a low-pass filter, it presents extremely low impedance to 50/60Hz fundamental mains frequency, which will not affect the normal power supply, working voltage and operating power of the equipment. Only useless high-frequency interference signals are consumed and suppressed.
    Q3: Why does my EMI filter work well in testing but fail in actual use? A: This issue is mainly caused by non-standard on-site installation. Long and messy wiring, insufficient grounding area, unreasonable installation position, and on-site complex electromagnetic environment will all weaken the filtering effect. Standard short-distance wiring and firm grounding are essential for consistent performance.
    Q4: Are AC EMI filters suitable for intermittent working equipment? A: Yes, this type of LC passive filter is fully adaptable to intermittent, frequent startup and standby working modes. It has no startup delay or performance attenuation during frequent power on and off, and can maintain stable filtering effects for long-term intermittent operation scenarios.
    Q5: What is insertion loss and why is it important for EMI filters? A: Insertion loss refers to the noise attenuation capacity of the filter at specific frequencies, which is the core indicator to judge filtering performance. Higher insertion loss means stronger suppression ability for corresponding frequency noise. It directly determines whether the equipment can pass professional EMC detection and meet industry electromagnetic compatibility standards.
    Partner with the best.
    E-MAIL US
    vip6@szviip.com
    SUPPORT 24/7
    +86 19925448748
    CONTACT PERSON
    Vicky Lee
    Related Products
    Ready to work with us ?
    +86-19925448748
         +86-0755-29170376     
    Shenzhen VIIP Electronics Co., Ltd. is a professional EMC service provider. Mainly focusing on the R & D, production and sales of EMC anti-interference components.
    Contact Us

    2F building D Mao yuan industry area, Huan guan south road,

    Guan hu street, Long hua district, Shenzhen city

    Contact person: Vicky Lee

    Tel: +86 19925448748

    WhatsApp:86-18003057179

    Copyright © 2026 VIIP | Sitemap | Privacy Policy
    Customer service
    detect