loading

The world's leading manufacturer of power filters.

VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 1
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 2
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 3
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 4
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 5
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 6
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 7
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 1
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 2
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 3
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 4
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 5
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 6
VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 7

VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices

50/60Hz Mains Noise Suppression Filter Unit
High Hi‑pot Withstand & Excellent Insulation Resistance It passes 2000VAC line‑to‑ground and 1450VDC line‑to‑line one‑minute high‑voltage test. Insulation resistance reaches above 100M Ohm under 500VDC between input/output and ground. Great dielectric strength effectively prevents electric breakdown risk and improves long‑term operation reliability.
5.0
design customization

    oops...!

    no product data.

    Go to homepage
    inlet socket
    VIP4‑1A-03(B041W0674)

    Product Brief

    The VIP4-1A-03 is a premium single-phase AC EMI filter engineered with optimized LC passive circuit architecture. Designed with a 3A RMS rated current, it supports dual universal AC voltages of 115VAC and 250VAC, perfectly compatible with global 50/60Hz mains power grids. Boasting ultra-low leakage current and robust dielectric withstand performance, this filter delivers consistent and reliable electrical performance across a wide temperature spectrum ranging from -25℃ to 100℃. It features superior insertion loss capability, effectively suppressing both common-mode and differential-mode high-frequency electromagnetic interference on AC power lines. This component assists end devices in passing strict EMC compliance certifications, maintains stable quality consistency for large-scale manufacturing, and ensures secure, trouble-free long-term operation for all AC-powered electronic and electrical equipment.
    VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 8

    Application Range & Usage

    This single-phase EMI power filter is specially engineered to eliminate grid-derived noise and circuit electromagnetic interference, serving as an essential EMC optimization component for both industrial and consumer electronic devices worldwide.
    Its versatile application scenarios include:
    • Industrial automation systems and industrial control hardware
    • Switching power supplies, power adapters and portable battery chargers
    • Commercial office equipment and daily consumer electronics products
    • High-precision testing devices and professional measurement instruments
    • Household electrical appliances equipped with standard AC mains input terminals
    Installed at the front-end AC power input of electronic equipment, the filter efficiently isolates high-frequency noise from the public power grid to protect internal precision circuits and core components from interference damage. Meanwhile, it restrains electromagnetic noise generated by the device’s internal operation from back-propagating to the power grid, preventing cross-interference with other adjacent electrical equipment and stabilizing the overall power supply environment.
    VIP4‑1A‑03 B041W0674 AC Line Noise Suppression Filter High Attenuation Filter For Industrial Control Devices 9

    FAQ 

    Q1: What is the working principle behind EMI power filters? A: EMI power filters rely on the collaborative filtering effect of inductors and capacitors. They present low impedance to standard 50/60Hz fundamental power frequency to guarantee normal power supply, while forming high impedance barriers for high-frequency interference signals. This mechanism effectively absorbs, isolates and attenuates various high-frequency electromagnetic noise, achieving EMC noise reduction and power purification purposes.
    Q2: Why do EMI filters fail EMC testing occasionally? A: The main causes include mismatched current or frequency parameters, incorrect input-output installation direction, irregular wiring and poor grounding. In addition, unreasonable equipment layout and excessive ambient electromagnetic radiation will also weaken the filtering effect, leading to unqualified EMC test results.
    Q3: Can multiple EMI filters be used in parallel or series? A: Series connection is feasible to enhance high-frequency noise attenuation for stricter EMC requirements. Parallel connection is allowed only for filters with identical specifications to increase overall current load capacity. Mismatched parameter pairing will cause performance imbalance and even safety hazards.
    Q4: What is the service life of a passive EMI filter? A: Under rated voltage, rated current and standard temperature working conditions, passive LC EMI filters feature ultra-long service life up to 8-10 years. Since there are no active chips or wearable parts, performance attenuation is extremely slow, ensuring long-term stable operation with basic regular inspections.
    Q5: What is the difference between medical-grade and ordinary industrial EMI filters? A: Medical-grade filters adopt stricter low-leakage current design to meet medical safety standards and avoid electric shock risks for human contact. Ordinary industrial filters focus more on high attenuation and cost performance, with relatively higher leakage current, which is not applicable for medical, wearable and human-direct-contact equipment.
    Partner with the best.
    E-MAIL US
    vip6@szviip.com
    SUPPORT 24/7
    +86 19925448748
    CONTACT PERSON
    Vicky Lee
    Related Products
    Ready to work with us ?
    +86-19925448748
         +86-0755-29170376     
    Shenzhen VIIP Electronics Co., Ltd. is a professional EMC service provider. Mainly focusing on the R & D, production and sales of EMC anti-interference components.
    Contact Us

    2F building D Mao yuan industry area, Huan guan south road,

    Guan hu street, Long hua district, Shenzhen city

    Contact person: Vicky Lee

    Tel: +86 19925448748

    WhatsApp:86-18003057179

    Copyright © 2026 VIIP | Sitemap | Privacy Policy
    Customer service
    detect